High voltage module for the field of nuclear monitoring

LEAD
Input: Red line: Input power positive end. (Yellow line: Input power negative end.)
Black line: Input power ground wire. Green line: Output voltage control end.
Output: White line: High voltage (HV end).
Notice: Input power ground wire and Output ground wire share – Black Line! (GND end).
Main Technical Parameters
1. Operating temperature range: Max.: -55℃ ~ +225℃.
2. Input voltage: +10V ~ +33V (±10 ~±16.5V).
3. Input current: Max.: 60mA.
4. Output voltage: 0V ~ -2500V (+500 ~ +2000V).
5. Output current: 250μA.
6. Temperature stability: Max.: ±40PPM/℃, Typ.: ±20PPM/℃.
7. Line regulation: ±0.1%(10% linear change).
8. Load regulation: ±0.05(50% load change).
9. Output ripple: Negative: 1.0Vp-p, Typ.: 200mVp-p.
Positive: 100mVp-p, Typ.: 50mVp-p.
(With recommend filter: 5mVp-p, Typ.: 1mVp-p.)
10. Shock resistance: 25G, 0~300Hz.
More: