Welcome to Beijing Energy Website
 
  My status Skype免费通话。
 
 

Products /High Voltage Module
HVD Series
High voltage module for the field of nuclear monitoring
 

 

LEAD
 
Input: Red line: Input power positive end.    (Yellow line: Input power negative end.)
            Black line: Input power ground wire.   Green line: Output voltage control end.
Output: White line: High voltage (HV end).
Notice: Input power ground wire and Output ground wire share – Black Line! (GND end).
 
Main Technical Parameters
 
1.       Operating temperature range: Max.: -55℃ ~ +225℃.
2.       Input voltage: +10V ~ +33V (±10 ~±16.5V).
3.       Input current: Max.: 60mA.
4.       Output voltage: 0V ~ -2500V (+500 ~ +2000V).
5.       Output current: 250μA.
6.       Temperature stability: Max.: ±40PPM/℃, Typ.: ±20PPM/℃.
7.       Line regulation: ±0.1%(10% linear change).
8.       Load regulation: ±0.05(50% load change).
9.       Output ripple: Negative: 1.0Vp-p, Typ.: 200mVp-p.
                                     Positive: 100mVp-p, Typ.: 50mVp-p.
                                     (With recommend filter: 5mVp-p, Typ.: 1mVp-p.)

10.    Shock resistance: 25G, 0~300Hz.

 

 

More:

 
Write a Review
*
 
Comment

No reviews yet, you come to the first one.


 
 